Fil-Tech, Inc.
Technical Bulletin No. 8
Stress Relieving, Longer Life, Alloy
Quartz Crystals
|
Fil-Techs quartz crystals are designed
to exactly replace original equipment
manufacturers crystals to insure trouble-free operation. In spite of this, Fil-Tech will often
tighten the OEMs specification to enhance crystal performance. The following specifications
are used in evaluating a crystal:
|
Physical Characteristics
|
Fil-Tech QI8008
|
|
Sensor material
|
Single crystal alpha quartz
|
|
Angle of cut 1
|
35 degrees 15 (AT)
|
|
Contour
|
3 diopter Plano-Convex
|
|
Surface Roughness
|
10 micron
|
|
Diameter
|
0.1550 (13.97 mm)
|
|
Electrode
|
Silver aluminum alloy/chromium
|
|
Electrical Characteristics 2
|
Fil-Tech QI8008
|
|
Resonant frequency (MHz)
|
5.975-5.993
|
|
Resistance at Resonance
|
<15 Ohms
|
|
Contact Resistance
|
<15 Ohms
|
Notes:
- The true angle of cut varies as a function
of the contour. The true angle for this
configuration crystal is actually 35 degrees 16 minutes.
- The electrical characteristics for Inficon
crystals were taken from a 100-piece sample
size and may vary in larger lot sizes. Fil-Tech values are actual quality assurance
specifications. A detailed histogram of Fil-Tech lot measurements is available on request.
Note:
Fil-Tech believes that high-level inspections are required to maintain the high quality
crystal production demanded by our end users. In addition to the electrical and physical
parameters listed above Fil-Tech measures motional capacitance and inductance, spurious
resonance separation, and static capacitance to help track subtle changes in incoming quartz
quality and in the production process.
Tel 800-743-1743 FIL-TECH INC. 617-742-0686 Fax
COPYRIGHT FIL-TECH INC. 1998
|